DMX Relais & Analoog 1 kanalen 0-10 Volt of 1-10 Volt - [ 2 Variants ]

The DMX Relais/Analog Interface 1 is designed for several kinds of controlling tasks.Potential free switch output
One potential free switch output (normally open / NO) with up to 8A switching capacity is available.Switching contact for direct and alternating voltage
The switching contact is suitable for switching both direct voltage and alternating voltage.Analog control output
One control output with 0-10V or 1-10V are available for control devices with analog input.For voltages from 12V up to 24V
The DMX Relais/Analog Interface 1 runs with supply voltages from 12 up to 24V direct voltage.DMX FAIL-Function
An adjustable DMX FAIL-Function offers the option to hold the current state (HOLD) or to adopt a predefined value if the DMX signal fails.RDM support
The DMX Relais/Analog Interface 1 the configuration via RDM or DMX.Several operating modes
The DMX Relais/Analog Interface 1 offers several operating modes which can be set via jumper or RDM:
- Relay + Analog 8Bit 0-10V
- Relay + Analog 8Bit 1-10V
- Relay + Analog 10Bit 0-10V
- Relay + Analog 10Bit 1-10V
- Relay & Analog 8Bit 0-10V
- Relay & Analog 8Bit 1-10V
- Relay & Analog 10Bit 0-10
- Relay & Analog 10Bit 1-10VTop hat rail mounting available
Suitable for the DMX Relais/Analog Interface 1 the DIN rail housing 350 is available as accessory.

Choose a variant:

Starting at 83.82 €
price incl. VAT excluding shipping cost